The Fermilab Muon g-2 experiment: Laser calibration system
Anno: 2017
Autori: Karuza M., Anastasi A., Basti A., Bedeschi F., Bartolini M., Cantatore G., Cauz D., Corradi G., Dabagov S., Di Sciascio G., Di Stefano R., Driutti A., Escalante O., Ferrari C., Fioretti A., Gabbanini C., Gioiosa A., Hampai D., Iacovacci M., Liedl A., Lusiani A., Marignetti F., Mastroianni S., Moricciani D., Nath A., Pauletta G., Piacentino G.M., Raha N., Santi L., Venanzoni G.
Affiliazione autori: Department of Physics, Centre for Micro Nano Sciences and Technologies, University of Rijeka, Radmile Matejcic 2, Rijeka, 51000, Croatia; INFN, Sezione di Trieste e G.C. di Udine, Via A. Valerio 2, Trieste, 34127, Italy; Laboratori Nazionali Frascati, INFN, Via Enrico Fermi 40, Frascati, 00044, Italy; Istituto Nazionale di Ottica Del C.N.R., Ss Pisa, Via Moruzzi 1, Pisa, 56124, Italy; Dipartimento MIFT, Università di Messina, Viale F. Stagno d\’Alcontres 31, Messina, 98166, Italy; INFN, Sezione di Napoli, Complesso Universitario di M. S. Angelo, Ed. 6-Via Cintia, Napoli, 80126, Italy; INFN, Sezione di Roma Tor Vergata, Via della Ricerca Scientifica 1, Roma, 00133, Italy; Dipartimento di Fisica, Università di Trieste, Piazzale Europa 4, Trieste, 34127, Italy; Università di Napoli, Napoli, Italy; DMIF, Università di Udine, Via delle Scienze 206, Udine, Italy; Università di Cassino, Cassino, Italy; INFN, Sezione di Pisa, Largo Pontecorvo 3, Pisa, 56127, Italy; Scuola Normale Superiore, Piazza dei Cavalieri 7, Pisa, 56126, Italy; INFN, Sezione di Lecce, Via Arnesano 0, Lecce, 73100, Italy; Università Del Molise, Pesche, Italy; PN Lebedev Physical Institute, Moscow, Russian Federation; NR Nuclear University MEPhI, MEPhI, Moscow, Russian Federation
Abstract: The anomalous muon dipole magnetic moment can be measured (and calculated) with great precision thus providing insight on the Standard Model and new physics. Currently an experiment is under construction at Fermilab (U.S.A.) which is expected to measure the anomalous muon dipole magnetic moment with unprecedented precision. One of the improvements with respect to the previous experiments is expected to come from the laser calibration system which has been designed and constructed by the Italian part of the collaboration (INFN). An emphasis of this paper will be on the calibration system that is in the final stages of construction as well as the experiment which is expected to start data taking this year.
Giornale/Rivista: JOURNAL OF INSTRUMENTATION
Volume: 12 (8) Da Pagina: C08019-1 A: C08019-9
Maggiori informazioni: Instituto Nazionale di Fisica Nucleare, INFN. National Research Nuclear University MEPhI, NRNU MEPhI. 690835. – This research was supported by Istituto Nazionale di Fisica Nucleare (Italy) and by the EU Horizon 2020 Researchand Innovation Programme under the Marie Sklodowska-Curie Grant Agreement No. 690835. SD would like to thank the support by the Competitiveness Program of National Research Nuclear University MEPhI.Parole chiavi: Detector alignment and calibration methods (lasers, sources, particle-beams); Cherenkov detectors; Optics; LasersDOI: 10.1088/1748-0221/12/08/C08019Citazioni: 1dati da “WEB OF SCIENCE” (of Thomson Reuters) aggiornati al: 2024-12-01Riferimenti tratti da Isi Web of Knowledge: (solo abbonati) Link per visualizzare la scheda su IsiWeb: Clicca quiLink per visualizzare la citazioni su IsiWeb: Clicca qui