Response to Comment on \”Probing the Ultimate Limit of Fiber-Optic Strain Sensing\”
Anno: 2012
Autori: Gagliardi G., Salza M., Avino S., Ferraro P., De Natale P.
Affiliazione autori: Consiglio Nazionale delle Ricerche–Istituto Nazionale di Ottica (INO) and European Laboratory for Non-Linear Spectroscopy (LENS), Comprensorio A. Olivetti, Via Campi Flegrei 34 I-80078 Pozzuoli (Naples), Italy
Abstract: Cranch and Foster argue that the strain resolution of our fiber resonator sensor is not limited by thermal noise. However, extension of common theoretical models to high-finesse passive resonators at low frequency needs further attention. Our findings are consistent with noise of thermodynamic nature for which no experimental evidence in the infrasonic range was available until recently.
Giornale/Rivista: SCIENCE
Volume: 335 (6066) Da Pagina: 286 A: 286
Parole chiavi: Acrylic acid; Silicon dioxide, acoustic analysis; Controlled study; Diode laser; elasticity; Energy; Fiber optic biosensor; Frequency analysis; Low frequency noise; Noise measurement; Note; Optical resolution; Oscillator; Phototherapy; Priority journal; Stress strain relationship; Temperature dependence; Thermal stimulation; Young modulusDOI: 10.1126/science.1205516Citazioni: 11dati da “WEB OF SCIENCE” (of Thomson Reuters) aggiornati al: 2025-01-12Riferimenti tratti da Isi Web of Knowledge: (solo abbonati) Link per visualizzare la scheda su IsiWeb: Clicca quiLink per visualizzare la citazioni su IsiWeb: Clicca qui