Chemical and isotopic analysis using diode laser spectroscopy: applications to volcanic gas monitoring
Anno: 2002
Autori: Gagliardi G., Restieri R., Casa G., Gianfrani L.
Affiliazione autori: Dipartimento Di Scienze Ambientali Della Seconda, Università Di Napoli, Via Vivaldi 43, I-81100 Caserta, Italy; INFM—Gruppo collegato all’, Università Di Napoli, Italy
Abstract: We report on a diode-laser-based spectrometer, operating at a wavelength of 2 mum, which enables for simultaneous measurements Of CO2 and H2O concentrations in gaseous mixtures with high precision and accuracy. We implemented the very simple approach of a direct measurement of absorption in a multiple reflection cell with a pathlength of 50 m. Gas concentration is simply retrieved from the integrated absorbance, without using calibration cells. The spectrometer is equipped with single-mode optical fibers in order to probe remote environments. The possible application in volcanic areas will be discussed. We also investigated the possibility to measure the isotopic ratio (CO2)-C-13/(CO2)-C-12, which is another relevant parameter for monitoring volcanic activity. (C) 2002 Elsevier Science Ltd. All rights reserved.
Giornale/Rivista: OPTICS AND LASERS IN ENGINEERING
Volume: 37 (2-3) Da Pagina: 131 A: 142
Parole chiavi: Absorption; Carbon dioxide; Chemical analysis; Mixtures; Single mode fibers; Spectrometers; Diode laser spectroscopy; Volcanic gas; Semiconductor lasersDOI: 10.1016/S0143-8166(01)00081-1Citazioni: 22dati da “WEB OF SCIENCE” (of Thomson Reuters) aggiornati al: 2024-09-01Riferimenti tratti da Isi Web of Knowledge: (solo abbonati) Link per visualizzare la scheda su IsiWeb: Clicca quiLink per visualizzare la citazioni su IsiWeb: Clicca qui